Conto D2 - B & D MID Certified Active Energy Meter - DIN Rail Mounting
Kilowatt hour meter / active energy meter
B and D MID Certified active energy meter
2 module DIN rail mounting
Single phase
Direct connection up to 63A, 240V, 50/60Hz
Active energy class B (EN50470)
Reactive energy class 2 (EN60253-23)
Total active energy
Partial active energy (resettable)
Current
Voltage
Active power (kW)
Frequency
Power factor
Hours run meter (resettable)
6 digit LCD display
Self supplied auxiliary
Pulsed output or RS485 Modbus communications
Unit Dimensions : H=91.5, W=35.6, D=65mm
|
Availability
Range Stocked
|
|
Conto D4-Pd MID - B & D MID Certified Active Energy Meter - DIN Rail Mounting
Kilowatt hour meter / active energy meter
B and D MID Certified active energy meter
4 module DIN rail mounting
Direct connection up to 63A
3 phase 4 wire network unbalanced load
Active energy class B (EN50470)
Reactive energy class 2 (EN60253-23)
Total active energy
Total reactive energy
Partial active energy (resettable)
Partial reactive energy (resettable)
Phase current
Phase – neutral voltage
Phase – phase voltage
Active power (KW)
Reactive power (KVar)
Apparent power (KVA)
Phase active power (KW)
Phase reactive power (KVar)
Active power demand
Active power max demand
Frequency
Power factor
Hours run meter (resettable)
230V/400V 50Hz measured voltage
8 digit LCD display
Self supplied auxiliary
Pulsed output and RS485 communications
Unit Dimensions : H=89mm, W=71.2mm, D=65.6mm
|
Availability
Range Stocked
|
|
Conto D4-Pt MID - B & D MID Certified Active Energy Meter - DIN Rail Mounting
Kilowatt hour meter / active energy meter
B and D MID Certified active energy meter
4 module DIN rail mounting
3 phase (3 or 4 wire) network unbalanced load
Active energy class B (EN50470)
Reactive energy class 2 (EN60253-23)
Power demand
Power max demand
Phase and neutral current
Phase to phase and phase to neutral voltage
Frequency
Phase active power
Phase reactive power
3 phase active/reactive and apparent power
Power factor
Hours run
-/5A current transformer operated
230V/400V 50Hz measured voltage
8 digit LCD display
Pulsed output and RS485 communications
Programmable CT ratio
Auxiliary supply 230V 50/60Hz
Unit Dimensions : H=89mm, W=71.2mm, D=65.6mm
|
Availability
Range Stocked
|
|
PRO1D - B & D MID Certified kWh Energy Meters - DIN Rail Mounting
Kilowatt hour meter / active energy meter
MID approved B+D
18mm wide DIN rail mounting
Single phase
LCD display
Up to 45A direct connection
Can be used for billing purposes
Accuracy class B (EN50470.03)
Pulsed output
400V 50/60Hz measured voltage
|
Availability
Range Stocked
|
|
PRO75D - B & D MID Certified kWh Energy Meters - DIN Rail Mounting
Kilowatt hour meter / active energy meter
MID approved B+D
75mm wide DIN rail mounting
Single phase
Up to 100A direct connection
6+2 digit LCD display
Accuracy class B (EN50470.3)
Pulse output or RS485 Modbus communications
230V 50/60Hz measured voltage
|
Availability
Range Stocked
|
|
Conto D2 - kWh Energy Meters - DIN Rail mounting
Kilowatt hour meter / active energy meter
2 module DIN rail mounting
Single phase network
Active energy class 1 (EN 62053-21)
Partial active energy (resettable)
Voltage, current (true RMS value)
Active power (kW)
Direct connection up to 36A or 63A, 240V, 50/60Hz
6 digit LCD display
Self supplied auxiliary
Optional pulsed output
Unit Dimensions : H=91.5, W=35.6, D=65mm
|
Availability
Range Stocked
|
|
Conto D4-Pd - kWh Energy Meters - DIN Rail mounting
Kilowatt hour meter / active energy meter
4 module DIN rail mounting
3 phase (3 or 4 wire) network unbalanced load
Active energy class 1 (EN62053-21)
Reactive energy class 2 (EN62053-23)
Partial active and reactive energy (resettable)
Power demand
Power max demand
Twin tariff
Direct connected up to 63A
190…440V phase to phase (50/60Hz) measured voltage
8 digit LCD display
Pulsed output or RS485 communications
Self supplied auxiliary
Unit Dimensions : H=89mm, W=71.2mm, D=65.6mm
|
Availability
Range Stocked
|
|
Conto D4-Sh - kWh Energy Meters - DIN Rail mounting
Kilowatt hour meter / active energy meter
4 Module DIN Rail mounting
Single phase & 3 phase (3 or 4 wire) network unbalanced load
Active energy class 1 (EN62053-21)
Reactive energy class 2 (EN62053-23)
Power demand
Power max demand (resettable)
Phase Current
Phase to phase and phase to neutral voltage
Frequency
Phase active power
Phase reactive power
3 phase active/reactive and apparent power
Power factor
–/1A or –/5A current transformer operated
190…440V 50/60Hz measured voltage
8 digit LCD display
Self supplied auxiliary
Pulsed output or RS485 communications
Programmable CT ratios
|
Availability
Range Stocked
|
|
Conto 72-Sh - kWh Energy Meters - Panel Mounting
Kilowatt hour meter / active energy meter
72 x 72mm flush panel mounting
Single phase & 3 phase (3 or 4 wire) network unbalanced load
Active energy class 1 (EN62053-21)
Reactive energy class 2 (EN62053-23)
Power demand
Power max demand (resettable)
Partial active and reactive energy (resettable)
Phase Current
Phase to phase and phase to neutral voltage
Frequency
Phase active power
Phase reactive power
3 phase active/reactive and apparent power
Power factor
–/1A or –/5A ct operated
190…440V 50/60Hz measured voltage
8 digit LCD display
Self supplied auxiliary
Pulsed output
Programmable CT ratios
|
Availability
Range Stocked
|
|
Conto D4-Pt - Energy Meter - DIN Rail Mounting
Kilowatt hour meter / active energy meter
4 module DIN rail mounting
Single phase or 3 phase (3 or 4 wire) network unbalanced load
Total active energy class 1 (EN62053-21)
Total reactive energy class 2 (EN60253-23)
Partial active energy
Partial reactive energy
Power demand
Power max demand
1A or 5A current transformer operated
230V/400V 50Hz measured voltage
8 digit LCD display
Pulsed output or RS485 communications
Programmable CT ratio
Self supplied auxiliary
Unit Dimensions : H=89mm, W=71.2mm, D=65.6mm
|
Availability
Range Stocked
|
|
Conto D4-Pd M-Bus - kWh Energy Meters - DIN Rail mounting
Kilowatt hour meter / active energy meter
4 module DIN rail mounting
3 phase (3 or 4 wire) network unbalanced load
Direct connected up to 63A
190…440V phase to phase (50/60Hz) measured voltage
Active energy class 1 (EN62053-21)
Reactive energy class 2 (EN62053-23)
Partial active and reactive energy (resettable)
Power demand
Power max demand
Dual tariff
8 digit LCD display
M-Bus communications
Self supplied auxiliary
Unit Dimensions : H=89mm, W=71.2mm, D=65.6mm
|
Availability
To Order
|
|
Conto D4-Pt M-Bus - Energy Meter - DIN Rail Mounting
Kilowatt hour meter / active energy meter
4 module DIN rail mounting
Single phase or 3 phase (3 or 4 wire) network unbalanced load
Total active energy class 1 (EN62053-21)
Total reactive energy class 2 (EN60253-23)
Partial active energy
Partial reactive energy
Power demand
Power max demand
Phase Current
Phase to phase and phase to neutral voltage
Phase active power
3 phase active/reactive and apparent power
1A or 5A current transformer operated
230V/400V 50Hz measured voltage
8 digit LCD display
Pulse output and M-Bus communications
Programmable CT ratio
Self supplied auxiliary
Unit Dimensions : H=89mm, W=71.2mm, D=65.6mm
|
Availability
To Order
|
|
PRO-2D
Kilowatt hour meter / active energy meter
36mm wide DIN rail mounting
Single phase
LCD display
Up to 80A direct connection
Accuracy class 1 (EN62053-21)
Pulsed output
230V 50/60Hz measured voltage
Unit Dimensions : H=140mm, W=36mm, D=70mm
|
Availability
|
|
EM368
Kilowatt hour meter / active energy meter
96 x 96mm flush panel mounting
Single phase and 3 phase (3 or 4 wire) network unbalanced load
Active energy class 1 (EN62053-21)
–/5A or 1A current transformer operated
Programmable CT ratio 5A…6000A
Direct measured voltage 100V...500V
Programmable VT ratio 100V...500KV
Semi conductor pulsed output
Available with RS485 communication
8 Digit LCD display
Self supplied auxiliary
Unit Dimensions : H=96mm, W=96mm, D=90mm
|
Availability
Range Stocked
|
|
AVKIT4 - D4 Flush Mounting Adaptor
4 module DIN rail energy meters flush panel mounting kit.
|
Availability
Stocked
|